PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
CCTSST-FR0.3 n×1×1.4 Railway Cables
Application
The CCTSST-FR0.3 n×1×1.4 Railway Cables are used as railway cables and can be installed directly into the ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Conductors
Soft annealed solid copper, 1.4 mm nominal diameter.
Insulation
PE insulation.
Stranding
Cores are helically stranded in concentric layers.
Core Wrapping
Two or more layers of plastic tape(s) with overlapping.
Screen
Copper tapes with overlap (protection against interference).
Inner Sheath
FRNC-PE sheath, coloured green.
Armour
Two layers of steel tape (0.8mm thick).
Outer Sheath
FRNC-PE sheath, coloured green.
*FRNC: Flame retardant, non corrosive.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 1.4 |
---|---|---|
Maximum Conductor Resistance | Ω/km | 11.7 |
Minimum Insulation Resistance @500 V DC | MΩ.km | 35000 |
Resistance Unbalance | % | 2 |
Test Voltage @50Hz 1min | ||
Core to Core | Veff | 2100 |
Core to Screen | Veff | 2500 |
Reduction Factor @100V/km 50Hz | 0.3 |
Mechanical and Thermal Properties
Minimum Bending Radius: 10×OD
Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)
Dimensions And Weight
Cable Code | Number of Cores |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
|
---|---|---|---|---|---|
Inner | Outer | ||||
1.4mm Conductor, 2.6mm Insulated Wire | |||||
RS/CCTSST-FR0.3-2Y(K)HBH-4C1.4 | 4 | 1.5 | 1.6 | 18.0 | 705 |
RS/CCTSST-FR0.3-2Y(K)HBH-19C1.4 | 19 | 1.6 | 1.8 | 26.1 | 1362 |
RS/CCTSST-FR0.3-2Y(K)HBH-27C1.4 | 27 | 1.6 | 1.8 | 29.2 | 1648 |
RS/CCTSST-FR0.3-2Y(K)HBH-48C1.4 | 48 | 1.7 | 1.8 | 36.7 | 2348 |